Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1942XXX-BD (Common Port Circuit Pack)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has
been physically removed from the system. This error type does not apply
to ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is
logged approximately 11 minutes after removal of the circuit pack or
failure of the SAKI Sanity Test (#53).
Table 9-720. Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test board UUCSS sh r 1
1(a) 0 Circuit pack removed
or SAKI Sanity Test
(#53)
MINOR ON
18(b) 0 busy-out board UUCSS WARNING OFF release board UUCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
217 (f) 0 None WARNING ON
257 65535 Control Channel Test
(#52)
MINOR ON test board UUCSS sh r 20
257 (g) Any None
267 (f) 0 None WARNING ON
513 (h) Any None MINOR ON test board UUCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit Test (#50) test board UUCSS l r 20
1281 (k) Ringing Application
Test (#51)
MINOR ON test board UUCSS r 2
1538 (l) Any None WARNING/
MINOR
ON
1793 (m) Neon Test (#220) MINOR ON test board UUCSS r 2
3840 (n) Any None
3999 (o) Any None