![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg31b.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-111ANN-BD (Announcement Circuit Pack)
9
Clock Match Inquiry Test (#212)
This test determines the state of the clock-generating circuitry on the
Announcement circuit pack. This circuitry is used to synchronize the
announcement board with the TDM clock carried on the PN’s backplane.
Table 9-42. TEST #211 Super Frame Match Inquiry
Error
Code
Te s t
Result Description/ Recommendation
2000 ABORT Response to the test request was not received within the allowable time
period. If Error Type 1538 is present in the Error Log, follow the
maintenance strategy recommended for this Error Type.
2100 ABORT Could not allocate the necessary system resources to run this test.
ABORT Internal system error.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL Test failed. Announcement playbacks should sound corrupted.
1. Reset the circuit pack via the reset board UUCSS command and then
run this test again. If the test continues to fail, replace the circuit pack
(see Warning).
2. If there are recurring alarms on this circuit pack caused by this test
failing, replace the circuit pack even if step 1 works.
!
WARNING:
Replacing the circuit pack will result in loss of integrated
announcements. See Essential Service Information.
PASS The speech processor can properly process record/playback requests.
User-reported troubles on this circuit pack should be investigated using
other circuit pack and port tests. Refer to “ANN-PT” for a description of the
port tests.
Continued on next page
Table 9-43. TEST #212 Clock Match Inquiry Test
Error
Code
Tes t
Result Description/ Recommendation
2000 ABORT Response to the test was not received within the allowable time period. If
Error Type 1538 is present in the Error Log, follow the procedure for that error.
2100 ABORT Could not allocate the necessary system resources to run this test.
ABORT Internal system error.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page