![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg1c9.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-146list measurements ds1
8
Parameters
Examples
list measurements ds1 2a18
list measurements ds1-log 2e01a
list measurements ds1-facility summary 2e01d schedule
Output
The following field descriptions pertain to the summary reports accessed by
list
measurements ds1
and
list measurements ds1-facility summary
.
UUCSS The location of a DS1 circuit pack.
UUCSS The location of a DS1 converter facility where
UUCSS
is the location of
the circuit pack and
f
is a letter (a-d) designating one of the four DS1
facilities.
Counted Since:
The start time and date when the associated measurement
counters were cleared, or when the DS1C circuit pack or facility
was administered.
Number of
Seconds Elapsed
Into Current
15-min
Interval:
The number of seconds from the beginning of the current
15-minute interval. This field has a value from 0 to 900.
Total of Valid
15-min
Intervals in
Past 24-hr
Period:
The total number of 15-minute intervals in the past 24-hour period
that contain valid data. This field has a value from 0 to 96.
Category
The following four fields report data form the error counters.
Errored Seconds
The value of the errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if
the data for the 15-minute interval is invalid.
Bursty Err Secs The value of the bursty errored seconds counter for the specified
15-minute interval. This field has a value from 0 to 900 or N/A if
the data for the 15-minute interval is invalid.
Severely Err
Secs
The value of the severely errored seconds counter for the
specified 15-minute interval. This field has a value from 0 to 900
or N/A if the data for the 15-minute interval is invalid.