A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-23ADX16D-B (16 Port AUDIX Circuit Pack)
9
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”.
Port-level maintenance is covered by ADX16D-PT.
DEFINITY AUDIX consists of 2 circuit packs that occupy 5 slots on a port carrier.
The tests described in this manual apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy of its own that is described in
DEFINITY AUDIX System Maintenance
, 585-300-110.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1. UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADX16D-B MINOR test board UUCSS sh AUDIX Circuit Pack
ADX16D-B WARNING test board UUCSS sh AUDIX Circuit Pack