6-44Automatic Transmission Measurement System (ATMS)
6
Test Call Results
If the test call successfully completes, and all trunks test within administered
thresholds for marginal and unacceptable performance, then a PASS result is
returned. If the test aborts or fails, an error code indicating the cause is returned.
The error codes are explained in the CO-TRK and TIE-TRK sections of Chapter 9,
‘‘ABRI-PORT (ASAI ISDN-BRI Port)’’. When the trunk is being used for call
Table 6-8. Measurement Capability by TTL Type
Terminating Test Line Type
Te st
105 Type
with Return
Loss
105 Type
without
Return Loss
High-level/
Low-level
Tone Source 100 Type 102 Type
1004 Hz Loss
Far-End to Near-End
xx xxx
1004 Hz Loss
Near-End to Far-End
xx
404 Hz Loss Far-End
to Near-End
xx x
404 Hz Loss
Near-End to Far-End
xx
2804 Hz Loss
Far-End to Near-End
xx x
2804 Hz Loss
Near-End to Far-End
xx
C-Message Noise
Near-End
xx xx
C-Message Noise
Far-End
xx
C-Notched Noise
Near-End
xx
C-Notched Noise
Far-End
xx
Return Loss
1
Near-End
1 Return Loss includes Singing Return Loss High Frequency, Singing Return Loss Low Frequency, and
Echo Return Loss.
xx xx
Return Loss Far-End