Maintenance Object Repair Procedures
9-1334PPP-PT (Control LAN Packet/Port)
9
PPP Link Status Inquiry Test (#1279)
This non-destructive test determines the state of the PPP link.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout port UUCSSpp
and reset board UUCSS).
2. If the problem persists, replace the circuit pack.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
1 FAIL System software indicates at least one PPP link session is down (SOME UP).
1. Isolate downed sessions (status port UUCSSpp or status link n).
Follow actions based on session information.
2 FAIL System software indicates all PPP sessions are down (ALL DOWN).
1. Test the port (test port UUCSSpp) to verify the SCOTCH Synchronous
Looparound Test (#1275) result.
2. If test passes, wait for system software to indicate ALL UP.
PASS All sessions up.
If the PPP link is: Then:
Connected The test passes
Disconnected The test fails
Table 9-521. TEST #1286 Session Status Test — Continued