Maintenance Object Repair Procedures
9-1327PPP-PT (Control LAN Packet/Port)
9
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures to verify repair.
3. Clear the alarm (
test port UUCSSpp long clear
).
c.
Error Type 513
: PPP link lost end-to-end connectivity.
1. Test for hardware problem (
test port UUCSSpp long
).
2. Run TDM Looparound Test (#1285) and refer to repair procedures if
there is a hardware problem.
If there is no hardware problem, the switch tries to re-establish PPP
link.
d.
Error Type 769
: Port received an invalid frame, which
■ is greater than the maximum length
■ contains CRC errors
■ violates the link level protocol.
1. Test the port (
test port UUCSSpp long
).
2. Refer to TDM Port Looparound Test (#1285) to verify repair.
3. Clear the alarm (
test port UUCSSpp long clear
).
e.
Error Type 1281
: System software received an indication that the far-end
has requested a disconnect of a session on this link. This is a log-only
error.
f.
Error Type 1537, 1538
: Some or all port sessions (sockets) are down.
g.
Error Type 1793-1920
: system software received an indication that a
socket was closed due to an error. Error Type indicates the application f
the application associated with this socket.
Aux Data indicates the internal application number.
h. Error Type 2305-2816: System software detected a session is down. Aux
Data indicates the session number.
If the switch indicates that: Then it:
Some of the sessions are down Raises off-board WARNING
All of the sessions are down Raises off-board MINOR alarm
Error Type Application
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway