A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1947XXX-BD (Common Port Circuit Pack)
9
Ringing Application Test (#51)
This test checks the ringing application circuitry common to all ports on an
Analog Line circuit pack.
Table 9-722. TEST #51 Ringing Application Circuit Test
Error
Code
Te s t
Result Description/ Recommendation
1000
2100
ABORT Could not allocate the necessary system resources to run test.
ABORT Could not allocate the necessary system resources to run test. The circuit
pack is not installed. Internal system error
2000 ABORT There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error log, follow the
maintenance strategy that is recommended for this error type.
2. Run the busyout board, reset board, and release busy board
commands,and then retest.
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if there are no problems
found, replace the circuit pack.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to Chapter 8, for a full
description of all possible states). You must wait until the port is idle
before retesting.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page