Tektronix AWG2005 Stereo System User Manual


 
Performance Tests
AWG2005 Service Manual
4Ć29
TableĂ4Ć4:ăClock Frequency Accuracy
Clock Frequency Frequency Range Frequency Range (Option 05)
10ĂMHz 9.9995ĂMHz - 10.0005ĂMHz 9.99995ĂMHz - 10.00005ĂMHz
1ĂMHz 0.99995ĂMHz1.00005ĂMHz 0.999995ĂMHz 1.000005ĂMHz
1ĂkHz 0.99995ĂkHz - 1.00005ĂkHz 0.999995ĂkHz - 1.000005ĂkHz
10ĂHz 9.9995ĂHz - 10.0005ĂHz 9.99995ĂHz - 10.00005ĂHz
4. End procedure: Disconnect the frequency counter.
Check Clock Amplitude
Electrical Characteristic Checked: Auxiliary Outputs, Clock, Amplitude,
on pageĂ1Ć14.
Equipment Required: A 50Ăcoaxial cable and an oscilloscope.
Prerequisites: The AWG2005 meets the prerequisites listed on page 4Ć7.
Procedure:
1. Install test hookup and set test equipment controls:
a. Hook up oscilloscope: Connect the AWG2005 rearĆpanel CLOCK
OUT connector through a coaxial cable to the oscilloscope CH1
vertical input (see Figure 4Ć12).
Oscilloscope
AWG2005
AWG2005
Figure 4Ć12:ăClock Amplitude Initial Test Hookup