Tektronix AWG2005 Stereo System User Manual


 
Performance Tests
AWG2005 Service Manual
4Ć27
3. End procedure: Remove equipment: Disconnect connections to the test
equipment.
These procedures check the accuracy of the AWG2005 clock frequency and
the waveform output amplitude.
Check Clock Frequency Accuracy
Electrical Characteristic Checked: Clock Generator, Accuracy, on
pageĂ1Ć11.
Equipment Required: A 50Ă coaxial cable and a frequency counter.
Prerequisites: The AWG2005 meets the prerequisites listed on page 4Ć7.
Procedure:
1. Install test hookup and set test equipment controls:
a. Hook up frequency counter: Connect the AWG2005 rear panel
CLOCK OUT connector to the frequency counter input through a
coaxial cable (see Figure 4Ć11).
AWG2005
AWG2005
Frequency Counter
DC 5010
Figure 4Ć11:ăClock Frequency Accuracy Initial Test Hookup
Clock Frequency and
Amplitude Checks