The following explains each item in the bottom menu.
H Clock Ċ This item sets the clock source and clock frequency. The
clock source can be set to either internal or external.
The clock period is the time between the data points for the waveĆ
form created. Therefore, the product of the clock period and the
number of waveform points is the waveform or sequence period. For
example, if the clock frequency is 1 MHz (period of 1 µs) and there
are 100 waveform points, the waveform period is displayed as 100
ms.
The clock source and clock frequency setting will be applied to all
channels.
H
Operation Ċ This item performs an arithmetic operation between
the CH1 waveform and CH2 waveform or external waveform, and
outputs the result at the CH1 output connector. The operations are
addition (Add, External Add) and multiplication (AM, External AM).
H Filter Ċ This item selects a filter that restricts the frequency band
for the output channel. Choose a 5, 2, 1 MHz, or 500ĂkHz filter, or
you can select Through (no filter).
H Ampl Ċ This selection sets the voltage value for the 12Ćbit, fullĆ
scale, output amplitude on the vertical scale. The amplitude can be
set in steps of 1ĂmV within the range from 0.05ĂV to 10ĂV.
H Offset Ċ This item sets the offset level of the output waveform. The
offset can be set in steps of 5ĂmV within the range ±5ĂV.
Operation Mode Settings
The MODE menu initiates the waveform output with the output conditions
set using the SETUP menu.
1. Push the MODE button in the MENU column. The MODE menu in
Figure 2Ć6 appears.
2. Select the operation mode from the bottom menu. The operation modes
are Cont, Triggered, Gated, Waveform Advance, and Autostep.
In all modes except Cont, the trigger or gate signal source can be the
external signal applied to the TRIGGER INPUT connector or can be
generated by pushing the front panel TRIGGER MANUAL button. The
following text describes the individual modes.
H
Cont Mode Ċ When you push the Cont button, the AWG2005
immediately outputs the specified waveform or sequence waveform
continuously.