Preparation for Use
Operating Information
2Ć6
Memory Backup Power
A lithium battery maintains internal nonvolatile memory, allowing the
AWG2005 to retain waveform and sequence files if AC power is lost. This
battery has a shelf life of about three years. Partial or total loss of stored
information at powerĆon may indicate that the battery needs to be replaced.
WARNING
To avoid risk of fire or explosion, replace the AWG2005 battery with
a lithium battery having the part number listed in section 10,MeĆ
chanical Parts List. This battery is a safetyĆcontrolled part.
To avoid risk of fire or explosion, do not recharge, rapidly disĆ
charge, or disassemble the battery; and do not incinerate the
battery or heat it above 100°ĂC. Also, dispose of used batteries
promptly. Small quantities of used batteries can be disposed of in
normal refuse. Keep lithium batteries away from children.
Your AWG2005 may include one or more options. To determine which opĆ
tions are installed, power on the AWG2005 and look at the display during
the powerĆon sequence. The AWG2005 lists the installed options after OpĆ
tions, near the top of the display.
Table 2Ć1 of this subsection gives information about line cord options. SecĆ
tion 7, Options, lists other options and optional accessories. For further
information and prices of options, see your Tektronix Products catalog or
contact a Tektronix Field Office.
Installed Options