Tektronix AWG2005 Stereo System User Manual


 
Performance Tests
Performance Verification
4Ć12
TableĂ4Ć3:ăFile List for Performance Check Disk (Cont.)
No. Usage
SETUP MenuEDIT Menu
File Name
No. Usage
OffsetAmplFilterOperationClock
Wfm
Point
Wfm
Shape
File Name
14 MS_SL.WFM
ă200 ăă1ĂMHz Normal Through 1ĂV 0ĂV
Master-Slave
Operation
Check (OpĆ
tional Check)
15 DIGI_OUT.WFM
4096 ăă1ĂMHz Normal Through 1ĂV 0ĂV
DIGITAL
DATA OUT
Check
(Option 04)
These procedures check operation of the Cont, Triggered, Gated, Waveform
Advance, and Autostep modes.
Check Cont Mode
Electrical Characteristic Checked: Operating modes, Continuous, on
pageĂ1Ć5.
Equipment Required: A 50Ăcoaxial cable and an oscilloscope.
Prerequisites: The AWG2005 must meet the prerequisites listed on
page 4Ć7.
Procedure:
1. Install the test hookup and set test equipment controls:
a. Hook up the oscilloscope: Connect the AWG2005 CH1 output
connector through the coaxial cable to the CH1 vertical input conĆ
nector on the oscilloscope (see Figure 4Ć3).
OscilloscopeAWG2005
AWG2005
Figure 4Ć3:ăCont Mode Initial Test Hookup
Operating Mode
Checks