Tektronix AWG2005 Stereo System User Manual


 
Performance Tests
AWG2005 Service Manual
4Ć47
13 Header2
Oscilloscope
Out Cable
Digital Data
AWG 2005 Rear Panel
Figure 4Ć21:ăDigital Data Out Initial Test Hookup
c. Set oscilloscope controls:
Vertical CH1
Scale 1ĂV/div.
Input Impedance 1ĂM
Horizontal
Sweep Adjust as needed
Trigger
Mode Auto
2. Create the AWG2005 waveform file, select waveform file, and set
AWG2005 controls:
a. Initialize AWG2005 controls: Push UTILITY!Misc!Config...!ReĆ
set to Factory!O.K.
b. Select waveform file:
H Push SETUP!Waveform Sequence, if necessary, to select a
waveform file for CH1. Waveform Sequence toggles between the
CH1 files (upper list) and the CH2 files (lower list).
H Turn the general purpose knob to highlight the DIGI_OUT.WFM
file.
H Push ENTER to select the file.
c. Set AWG2005 controls:
H Push MODE!Cont
3. Check the CH1 digital data output signals: