Alpine pmn CD Player User Manual


 
U41117-J-Z125-7-76 531
Explanation of console messages Message lines
SXVW046 VLPWATCH: NOTICE: VW(#046) AutoVLP-failover: SVLP is alive!
Meaning
The VLP logs that the SVLP is available.
SXVW047 VLPWATCH: ALERT: VW(#047) AutoVLP-failover: SVLP is not alive!
Meaning
The VLP logs that the SVLP is not available.
Response
The SVLP and its connections to the VLP must be checked.
SXVW048 VLPWATCH: ALERT: VW(#048) AutoVLP-failover: switch SVLP_to_VLP successfully
completed!
Meaning
The switchover of the SVLP to the VLP has been successfully completed. Files have been
created for restore purposes. The conditions are check again and normally the function is
terminated with message SXVW034.
Response
You must investigate the status of or fault on the failed VLP.
SXVW049 VLPWATCH: ALERT: VW(#049) AutoVLP-failover: switch VLP_to_SVLP successfully
completed!
Meaning
The switchover of the VLP to the SVLP has been successfully completed.
SXVW050 VLPWATCH: NOTICE: VW(#050) AutoVLP-failover: reboot after %d minutes if switch
VLP_to_SVLP doesn't terminate!
Meaning
If a switchover of “VLP to SVLP” runs for a very long time the system logs when a reboot
was executed every 5 minutes.
SXVW051 VLPWATCH: NOTICE: VW(#052) AutoVLP-failover: reboot after %d minutes if switch
SVLP_to_VLP doesn't terminate!
Meaning
If a switchover of “SVLP to VLP” runs for a very long time the system logs when a reboot
was executed every 5 minutes.
SXVW052 VLPWATCH: NOTICE: VW(#052) AutoVLP-Failover: read error of Licence!
Meaning
An error occurred while checking the license.
Response
Check the license.