Message lines Explanation of console messages
9.2.6 SXFC... (FibreChannel Driver)
SXFC026 PVA1ICP0 : FC2: IOCB_E_LOCAL_REJECT
ALERT
SXFC005 PVA1ICP0 : FC2: loop_id 0, IOCB error sequence timeout
None
Meaning
These two messages only occur together. The 'sequence timeout' indicates a problem
which was detected/caused by the Emulex firmware. A typical example is a data transfer
while writing or reading which is not terminated within the permissible maximum time. The
source of the error cannot be determined from this. The error describes a situation which
occurs on FC-PH-2 protocol level. Use of an FC analyzer is generally required for a precise
analysis.
SXFC026 FC3: IOCB_E_LOCAL_REJECT
ALERT
SXFC005 FC3: loop_id 0, IOCB error invalid RPI
None
Meaning
These two messages only occur together and can be output when individual ISPs or the
entire CentricStor system is/are rebooted. They are issued only when certain switch
firmware revisions are used and can be ignored.
SXFC026 ICP1 : FC2: IOCB_E_LOCAL_REJECT
ALERT
SXFC005 ICP1 : FC2: loop_id 0, IOCB error abort requested
None
The CentricStor ISP concerned has aborted an I/O operation.
Response
Notify the maintenance staff.
SXFC028 FC self initiated abort
ALERT
Meaning
This message is issued when the CentricStor FC driver aborts an IO after a timeout of 2
minutes. The timeout generally concerns a data transfer which has not been completed. In
exceptional cases the abortion can also apply for commands which the CentricStor FC
driver has issued for the Emulex board and which have not been answered after 2 minutes.
The timeout can be triggered by faulty behavior of the firmware on the host or CentricStor
side. The precise cause of the problem can only be determined by also using an FC
analyzer.
Response
If the problem occurs frequently you must notify the maintenance staff.