Alpine pmn CD Player User Manual


 
U41117-J-Z125-7-76 509
Explanation of console messages Message lines
SXSM501 sma#: BIOS Boot Retry Counter countdown occurred - maybe watchdog timeout
ALERT
Meaning
The Boot Retry Counter
1
(BIOS setup, menu item Server) has timed out.
Response
Notify maintenance staff.
SXSM502 sma#: Internal error at communication with autoss
ALERT
Meaning
Internal communication to the autoss process (for shutting down the system) is down. One
reason for this could be that autoss has been terminated.
Response
Notify maintenance staff.
SXSM503 sma#: Internal error at communication with <name> driver
ALERT
Meaning
Internal process communication to Server Management driver <name> is down.
Response
Notify maintenance staff.
SXSM509 sma#: Internal error at HW-access
ALERT
Meaning
An error occurred during internal accesses to hardware components containing information
for monitoring the server.
Response
Notify maintenance staff.
1
The Boot Retry Counter defines the maximum number of attempts that may be made to start the SINIX system after an error
has occurrred. This relates to errors such as software watchdog timeout or server shutdown owing to the temperature being too
high. The automatic SINIX reboot after a system failure with crash dump is not dependent on this mechanism. With each SINIX
reboot following such an error the Retry Counter is decremented. If the Retry Counter has reached the value 0, no automatic
SINIX reboot takes place when the next fault occurs.