Alpine pmn CD Player User Manual


 
U41117-J-Z125-7-76 489
Explanation of console messages Message lines
Response
In the event of a message with the error weight ALERT: Notify maintenance staff.
Example
SXRD003 s80d: RAID: ALERT: #212215 Enclosure 3, Power Supply 2 Critical
Connection between status and error weighting:
OK NOTICE
Warning WARNING
Not Available ERROR
Unknown ERROR
Critical ALERT
Not Installed ALERT
Messages with the error weighting ALERT trigger a teleservice call. For the S80 this
applies to all faulty components with the status “Critical” or “Not Installed” (faulty hard
disks have the status “Not Installed”).
A hardware fault can result in several different messages.
SXRD009 s80d: RAID: NOTICE: Raid<raid#>: <ccnt> Controller OK
Meaning
When the monitoring daemon starts (for example on reboot), information is read from the
connected FibreCAT S80 and the number of RAID controllers found per S80 is displayed
on the console.
The terms used here have the following meanings:
raid# Number of the RAID system (1 – 8)
ccnt# Number of the Controller (1 or 2)
9.2.15.3 FibreCAT CX500 and CX3-20 messages
SXRD010 RAID: ALERT <raid-id> Raid<raid#>: not all HBAs of <isp-name> registered
Where:
<raid-id> ID of the FibreCAT (target# of the two RAID controllers)
<raid#> Sequence RAID# (1 - 8)
<isp-name> Name of the ISP concerned
Meaning
One or both HBAs of the specified ISP are not registered in the FibreCAT named.
Response
Notify maintenance staff.