Message lines Explanation of console messages
SXVW038 VLPWATCH: NOTICE: VW(#038) AutoVLP-Failover: VLP is alive: wait max. 180 seconds
before a failover, if VLP is not alive
Meaning
The VLP has already provided a sign of life in the extended monitoring time of 7 or 5 minutes
in the boot or start phase; the monitoring time is now reduced to 3 minutes (default).
This message can only occur on the current SVLP.
SXVW039 VLPWATCH: NOTICE: VW(#039) AutoVLP-Failover: reboot to switch!
Meaning
A manual VLP switchover was initiated via “swap master”. The VLP is therefore rebooted.
This message can only occur on the current VLP.
SXVW040 VLPWATCH: NOTICE: VW(#040) AutoVLP-Failover: open error of /etc/vtls/
vlpwatch_started (errno=%d); terminated
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW041 VLPWATCH: NOTICE: VW(#041) AutoVLP-Failover: lock error of /etc/vtls/
vlpwatch_started (errno=%d), terminated
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW042 VLPWATCH: NOTICE: VW(#042) AutoVLP-Failover: open error of /etc/vtls/
vlpwatch_daemon_started (errno=%d); terminated!
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW043 VLPWATCH: NOTICE: VW(#043) AutoVLP-Failover: lock error of /etc/vtls/
vlpwatch_daemon_started (errno=%d), terminated!
Meaning
The AutoVLP failover function was started a second time on this ISP. That is not permissible
and is prevented!
SXVW044 VLPWATCH: NOTICE: VW(#044) AutoVLP-Failover: VLP is alive!
Meaning
The SVLP logs that the VLP is available.
SXVW045 VLPWATCH: NOTICE: VW(#045) AutoVLP-failover: VLP is not alive (%d Seconds)!
Meaning
The SVLP has not been able to reach the VLP for %d seconds!