U41117-J-Z125-7-76 497
Explanation of console messages Message lines
9.2.21 SXSM... (Server Management)
The term “sma#” used in this description is a collective term for the process names “sma”,
“sma02”, “sma03”, “sma04”, “sma05” and “sma06” which are specified in the error
messages in accordance with the hardware type of the SINIX server.
With the fan messages, the fan IDs <Id> have the following meaning:
SysFanx System fan number x (e.g. SysFan3)
Cpux Fan CPU fan number x (e.g. Cpu0 Fan)
PSx Fan Power supply fan number x (e.g. PS1 Fan)
All error messages are also recorded in the default log file via V3 logging.
SXSM001 sma#: Power supply <Id> is not present
ALERT
Meaning
Redundant power supply module <Id> has not been installed.
Response
Notify maintenance staff.
SXSM002 sma#: Power supply <Id> is present and failed
ALERT
Meaning
Redundant power supply module <Id> has failed.
Response
Notify maintenance staff.
SXSM004 sma#: Fan <Id> is not working
ALERT
Meaning
Fan <Id> has failed and must be replaced. If the fan is inoperable for more than 3 minutes,
the SINIX system is shut down and the server deactivated to prevent the server from
overheating.
Response
Notify maintenance staff.
SXSM006 sma#: *** SHUTDOWN *** (Shutdown because of defective Fan [<Id>])
ALERT
Meaning
The SINIX system is shut down because a fan is defective and the server deactivated to
prevent the server from overheating.