GXCC Function bar
Option is not set:
If a volume contains valid data, an error message is output and the volume is not
deleted.
Option is set:
A “Move” is carried out automatically for volumes containing valid data. The volume is
then removed from the data maintenance system.
Buttons along the bottom border
OK
The specified volumes are removed from the PLM data maintenance system.
Cancel
The window is closed without any further activity.
Actions linked with “OK”
In the event on an Erase, the first record of the volume (tape header) is overwritten in such
a way that the entire contents of the volume can no longer be accessed using CentricStor
resources.
When removing the cleaning cartridges, the number of cleaning cycles that remain are
modified if the cartridge has not been used completely.
You must make sure that the deletion of the volumes does not result in the number
of empty volumes falling below the minimum level. If this occurs a warning will be
output.
Before removing volumes from the archive physically, you must remove them
logically from the PLM data maintenance system. This process can take some time
since each volume must be loaded into a drive so that its tape header can be
overwritten. If the “ReorganizeFirst” flag is set, you must also add the time required
for reorganization. With “Show Physical Volumes” you can determine whether the
action has been completed.