120 U41117-J-Z125-7-76
Main window GXCC
● Left half of screen
– Circuit diagram of CentricStor
● Right half of screen
– System information
– Information field
● Line with the last console alarm message and acknowledgment button
● Footer
6.1.2 Loss of a connection
If the connection to the InfoBroker is lost, the data displayed will no longer be current. An
attempt is made to establish a new connection approximately every 20 seconds.
In the line for console messages a message will appear that the display is no longer up to
date: “Displayed data invalid. Reconnecting”.
All the objects displayed are invalid during this waiting period. On the function bar, only
“Unit” (selection of another CentricStor system) and “File” (to terminate GXCC) are active.
These allow you to select a different CentricStor system or terminate GXCC. You can thus
terminate GXCC or select another unit.
After the connection has been restored, the message “Reconnected” appears in the
message line. This remains displayed until it is overwritten by a new console alarm
message.
XTCC is not directly affected by the loss of the connection between the InfoBroker and
GXCC.
In some cases, the main window displays exclusively ISPs that are not ready for
operation (pink symbols) in this situation. This indicates that the loss of the
InfoBroker connection was caused by this component being shut down.
i