U41117-J-Z125-7-76 493
Explanation of console messages Message lines
SXRP019 RPLM(#19): NOTICE: job canceled on PDS <pds>, PV <pv>, state <state>
Meaning
The PLS or the PDS could not execute a job because of a timeout.
<state> Describes the command in which the timeout occurred.
For the PLS:
PLS_INSPECT
MOUNT
UMOUNT
For the PDS:
PDS_INSPECT
RDIR
INIT
UNLOA
The command is extended by the suffix _SENT_TIMECHECK.
After the RPLM has started, the commands PLS_INSPECT, UMOUNT and UNLOAD
can be preceded by 'INITIAL_' in the initialization phase. This occurs if a PV
was mounted in a PDS.
Response
The RPLM repeats the command automatically. If the message appears frequently, check
the device and/or the communication path. Notify maintenance staff if necessary.
SXRP022 RPLM(#22): ERROR: PLS reports VSN_NOEXIST on PDS <PDS-name>, PV <PV-name>
Meaning
The robot does not recognize the physical volume <PV-name>.
Response
This may be temporary. You should nevertheless check whether the relevant tape cartridge
is known to the robot. Notify maintenance staff if necessary.
SXRP027 RPLM(#27): ALERT: Number of LVs over maximum
Meaning
The number of logical volumes is above the permitted maximum.
Response
Correct the configuration or remove some logical volumes with the command
plmcmd dele -v <VSN>.
SXRP028 RPLM(#28): NOTICE: Number of LVs under maximum again
Meaning
The number of logical volumes is again below the permitted maximum.