Emerson Model 1700 Satellite Radio User Manual


 
Option Description
Disabled (default) Operators cannot start and stop totalizers and inventories from the dis-
play.
5.2.2 Enable or disable Totalizer Reset from the display
Display (standard) OFF-LINE MAINT > OFF-LINE CONFG > DISPLAY > TOTALS RESET
Chinese-language
display
Offline Maintain > Configuration > Display > Reset Total
ProLink II ProLink > Configuration > Display > Display Options > Display Totalizer Reset
ProLink III Device Tools > Configuration > Totalizer Control Methods
Field Communicator Configure > Manual Setup > Display > Display Variable Menu Features > Totalizer Reset
Overview
You can configure whether or not the operator is able to reset totalizers from the display.
Restrictions
This parameter does not apply to inventories. You cannot reset inventories from the display.
You cannot use the display to reset all totalizers as a group. You must reset totalizers
individually.
If the petroleum measurement application is installed on your computer, the operator must
enter the off-line password to perform this function, even if the off-line password is not
enabled.
Procedure
1. Ensure that the totalizers you want to reset have been configured as display
variables.
If the totalizer is not configured as a display variable, the operator will not be able to
reset it.
2. Enable or disable resetting the totalizer as desired.
Option Description
Enabled Operators can reset a totalizer from the display, if the totalizer is config-
ured as a display variable.
Disabled (default) Operators cannot reset totalizers from the display.
Configure device options and preferences
Configuration and Use Manual 65