Emerson Model 1700 Satellite Radio User Manual


 
Smart Meter Verification – Top-level menuFigure 9-11:
Run Verify Read Results Schedule Verify Exit
Down Down Down
Down Select
Select Select Select
*This option is displayed only if the transmitter is connected
to an enhanced core processor (V3.6 or higher) and the
meter verification software is installed on the transmitter.
Online Verify*
Select
Down
Select
Process variable
display
Up
Select
2. Scroll to Schedule Verify and press Select.
3. To schedule a single test or the first test in recurring execution:
a. Scroll to Set Next and press Select.
b. Enter the number of hours that the transmitter will wait before beginning the
test.
4. To schedule recurring execution:
a. Scroll to Set Recur and press Select.
b. Enter the number of hours that will elapse between tests.
5. To disable scheduled execution:
To disable execution of a single scheduled test, set Set Next to 0.
To disable recurring execution, set Set Recur to 0.
To disable all scheduled execution, choose Turn Off Schedule when you enter the
Smart Meter Verification menu.
Measurement support
150 Micro Motion
®
Model 1700 Transmitters with Analog Outputs