Configure Display Variable 1 to track the primary mA output
Display (standard) OFF-LINE MAINT > OFF-LINE CONFG > DISPLY > VAR 1
Chinese-language
display
Offline Maintain > Configuration > Display > Configure 1st Var
ProLink II ProLink > Configuration > Display > Var1
ProLink III Device Tools > Configuration > Transmitter Display > Display Security
Field Communicator Configure > Manual Setup > Display > Display Variables
Overview
You can configure Display Variable 1 to track mA Output Process Variable for the primary mA
output. When tracking is enabled, you can control Display Variable 1 from the display menu.
Tip
This feature is the only way to configure a display variable from the display menus (standard display
option only), and it applies only to Display Variable 1.
Procedure
Configure Display Variable 1 to track the primary mA output.