28—UTILITY Menu Parameters
Roland VS-2480 Owner’s Manual www.rolandus.com 367
DISPLAY
DISPLAY OFFSET TIME
This parameter is explained in “Shifting the Project Start Time” on Page 316.
TIME DISPLAY FORMAT
This parameter is explained in “Shifting the Project Start Time” on Page 316.
PEAK HOLD Sw
You can set the VS-2480’s level meters so that their peak lines “stick” at their highest
positions, remaining there until you press HOME•DISPLAY to release them. This
allows you to look away from the display without worrying that you’ll miss problematic
level peaks. To make the peak lines stick, set PEAK HOLD Sw to On. To return them to
their normal behavior, turn the parameter off.
PLAYREC
RECORD MONITOR
RECORD MONITOR is explained in “Simple Monitoring” on Page 191.
MARKER STOP
MARKER STOP lets you set the hard disk recorder so that it automatically stops when
the timeline reaches the next marker. This can be handy when you want the VS-2480 to
stop playback at the end of a section on which you’re working: place a marker at the
desired location and turn this parameter on. When MARKER STOP is off, the hard disk
recorder operates normally.
FADE CURVE
When you record, punch in and out, and edit tracks, the VS-2480 adds a very short
crossfade between pieces of audio to ensure that there are no clicks or pops where they
meet. The FADE CURVE parameter sets the shape of the crossfade. Set it to:
•
Linear
—so that the crossfade is linear in terms of digital audio data values.
•
Exp (Exponential)
—so that the crossfade is linear in terms of audibility.
UTILITY menu
F4 (PlyRec)
VS2480OMUS.book 367 ページ 2006年2月7日 火曜日 午後4時16分