Delay
Time
Use this control to specify the delay in milliseconds. The range of values is between
0ms and the maximum delay time of the processor block, in this case 150ms. The
default value is 0ms.
Distance
Use this control to specify the delay by distance. The range of values varies,
depending on the maximum delay time, but the default is always zero. Select the
appropriate unit of measure with the radio buttons to the right of the control.
When English units are selected, you can choose between inches or feet. When Metric units are selected, dis-
tance is indicated in meters.
Air Temperature
Use this control when you are setting the delay by distance, since the speed of
sound is affected by air temperature. The range of values is from -13°F to
122°F, or -25°C to 50°C. When English units are selected, air temperature is
indicated in Fahrenheit. When Metric units are selected, air temperature is indicated in Celsius. The default
value is 69° Fahrenheit or 20° Celsius.
Bypass
Clear
Click this button to reset the processor to its system default settings.
Link Indicator
This displays the link status of the processor. Any setting you change in a linked processor will change for all
other processors in the same link group. For a complete explanation of linking and link groups, see the
Linking section on page 24.
Bypass active
Click to pass signal through without altering it. When bypass is
active, the button appears lighted in red. The default setting is
inactive.
Bypass inactive
Processor Linked
Processor Not Linked