Shure DFR22 Stereo System User Manual


 
© 2003 Shure Incorporated DFR22 Software Guide 36
Importing ASCII Files
Importing ASCII Files
EQ processor windows and the combined response window can display data contained in an ASCII file, as shown in the
following illustration of a “PEQ10+CS” window.
Use the ASCII file import feature to display frequency vs. magnitude information measured in Smaart or TEF. By inverting
the data, you can use the display as a visual guide when setting EQ parameters. The display only shows amplitude values
for frequencies contained in the file; it does not interpolate a line between actual measured points. Consequently, there
may be empty space in the display, particularly at low frequencies.
The ASCII import feature is compatible with the following formats:
Transfer function measurements in SIA-Smaart
®
Pro (versions 2/x and 3.x), and SIA SmaartLive™.
TDS measurements in all versions of TEF™ TDS software for Windows and DOS, and EFC measurements in
TEF SLX software.
Saving Files in ASCII Format
Smaart Files
To export a measurement using Smaart software, measure in Transfer Function Mode. Then select
[File>ASCII Save] from the Smaart application menu.