Emerson Process Management 1500 Satellite Radio User Manual


 
76 Micro Motion
®
Model 1500 Transmitters with the Filling and Dosing Application
Using the Filling and Dosing Application
Figure 8-7 Fill sequences: Three-position analog valve
Normal operation
Valve behavior with PAUSE/RESUME at x%
0%
Full flow
Partial
flow
m% Closedn%
Configured values
Open Full: m%
Closed Partial: n%
0% m% Closedn%x%
0% m+x% Closedn%x%
m+x%
0% m% Closedx%n%
x% after Open Full and before
Closed Partial
x% after Closed Partial
m%
x% before Open Full