96 Micro Motion
®
Model 1500 Transmitters with the Filling and Dosing Application
Troubleshooting
A011 Cal Fail, Too Low Ensure that there is no flow through the sensor, then retry.
Cycle power to the flowmeter, then retry.
A012 Cal Fail, Too High Ensure that there is no flow through the sensor, then retry.
Cycle power to the flowmeter, then retry.
A013 Cal Fail, Too Noisy Remove or reduce sources of electromechanical noise, then attempt the
calibration or zero procedure again.
Sources of noise include:
• Mechanical pumps
• Pipe stress at sensor
• Electrical interference
• Vibration effects from nearby machinery
Cycle power to the flowmeter, then retry. See Section 11.22.
A014 Transmitter Error Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A016 Sensor RTD Error Check the test points. See Section 11.23.
Check the sensor coils. See Section 11.25.
Check wiring to sensor. See Section 11.14.2.
Make sure the appropriate sensor type is configured. See Section 4.2.
Contact Micro Motion. See Section 1.8.
A017 Meter RTD Error Check the test points. See Section 11.23.
Check the sensor coils. See Section 11.25.
Contact Micro Motion. See Section 1.8.
A018 EEPROM Failure Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A019 RAM Failure Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A020 Cal Factors Missing Check the characterization. Specifically, verify the FCF value. See Section 4.2.
A021 Sensor Type Incorrect Check the characterization. Specifically, verify the K1 value. See Section 4.2.
A022
(1)
CP Configuration Failure Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A023
(1)
CP Totals Failure Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A024
(1)
CP Program Corrupt Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A025
(1)
CP Boot Program Fault Cycle power to the flowmeter.
The transmitter might need service. Contact Micro Motion. See Section 1.8.
A026 Xmtr Comm Problem Check the wiring between the transmitter and the core processor (see
Section 11.14.2). The wires may be swapped. After swapping wires, cycle
power to the flowmeter.
Check for noise in wiring or transmitter environment.
Check the core processor LED. See Section 11.24.
Check that the core processor is receiving power. See Section 11.14.1.
Perform the core processor resistance test. See Section 11.24.2.
Table 11-4 Status alarms and remedies continued
Alarm