82 Digitizers Command Reference Chapter 3
SAMPle:SLOPe
SAMPle:SLOPe POS | 1 | NEG | 0 sets the slope of the sample signal (the
active edge, rising or falling, of the sample signal). The slope setting
is common to all channels.
Comments Sample Source Must be EXTernal: This command is effective only when the
sample source is EXTernal. The slope is set but will be ignored if the sample
source is a source other than EXTernal.
Executable when initiated: NO
Coupled command: NO
Reset (*RST) condition: POSitive (1)
SAMPle:SLOPe?
SAMPle:SLOPe? queries the present setting of the slope of the sample
signal. The sample slope is effective only when the sample source is
EXTernal.
SAMPle:SOURce
SAMPle:SOURce HOLD | TIMer | TTLT0-7 | EXT sets the source of the sample
signal which causes a measurement to be made. The sample source is
common to all channels. TIMer uses the internal time base. The EXTernal
input is the TTL “Sample” input pin on the front panel External Trigger Input
(D-subminiature) connector (left pin column, bottom pin).
E1563A E1564A
(“Sample” input - bottom left pin)