Agilent Technologies E1564A Stereo Receiver User Manual


 
68 Digitizers Command Reference Chapter 3
reg_number Register Description (base + register offset)
0 Manufacturer ID Register (base + 00
16
)
1 Device Type Register (base + 02
16
)
2 Status/Control Register (base + 04
16
)
3 Offset Register (base + 06
16
)
4** FIFO High Word Register (base + 08
16
)
5** FIFO Low Word Register (base + 0A
16
)
6 Interrupt Control Register (base + 0C
16
)
7 Interrupt Sources Register (base + 0E
16
)
8 CVTable Channel 1 Register (base + 10
16
)
9 CVTable Channel 2 Register (base + 12
16
)
10 CVTable Channel 3 Register (base + 14
16
)
11 CVTable Channel 4 Register (base + 16
16
)
12 Samples Taken High Word Register (base + 18
16
)
13 Samples Taken Low Word Register (base + 1A
16
)
14 Calibration Flash ROM Address Register (base + 1C
16
)
15 Calibration Flash ROM Data Register (base + 1E
16
)
16 Calibration Source Register (base + 20
16
)
17 Cache Count Register (base + 22
16
)
18 Range, Filter, Connect Chs 1 and 2 Register (base + 24
16
)
19 Range, Filter, Connect Chs 3 and 4 Register (base + 26
16
)
20 Trigger/Interrupt Level Channel 1 Register (base + 28
16
)
21 Trigger/Interrupt Level Channel 2 Register (base + 2A
16
)
22 Trigger/Interrupt Level Channel 3 Register (base + 2C
16
)
23 Trigger/Interrupt Level Channel 4 Register (base + 2E
16
)
24 Sample Period High Word Register (base + 30
16
)
25 Sample Period Low Word Register (base + 32
16
)
26 Pre-Trigger Count High Register (base + 34
16
)
27 Pre-Trigger Count Low Register (base + 36
16
)
28 Post-Trigger Count High Register (base + 38
16
)
29 Post-Trigger Count Low Register (base + 3A
16
)
30 Trigger Control/Source Register (base + 3C
16
)
31 Sample Control/Source Register (base + 3E
16
)
* DIAG:PEEK? 4 or DIAG:PEEK? 5 may cause an error if they are read
before data has been taken.