API reference tables, associated process fluids, and associated calculation values (continued)Table 4-11:
Table
name Process fluid CTL source data Reference temperature Density unit
5B Generalized products Observed density and
observed temperature
60 °F (non-configurable) Degrees API
Range: 0 to 85
5D Lubricating oils Observed density and
observed temperature
60 °F (non-configurable) Degrees API
Range: −10 to +40
6C Liquids with a constant
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
60 °F (non-configurable) Degrees API
23A Generalized crude and
JP4
Observed density and
observed temperature
60 °F (non-configurable) Relative density
Range: 0.6110 to 1.0760
23B Generalized products Observed density and
observed temperature
60 °F (non-configurable) Relative density
Range: 0.6535 to 1.0760
23D Lubricating oils Observed density and
observed temperature
60 °F (non-configurable) Relative density
Range: 0.8520 to 1.1640
24C Liquids with a constant
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
60 °F (non-configurable) Relative density
53A Generalized crude and
JP4
Observed density and
observed temperature
15 °C (configurable) Base density
Range: 610 to
1075 kg/m
3
53B Generalized products Observed density and
observed temperature
15 °C (configurable) Base density
Range: 653 to
1075 kg/m
3
53D Lubricating oils Observed density and
observed temperature
15 °C (configurable) Base density
Range: 825 to
1164 kg/m
3
54C Liquids with a constant
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
15 °C (configurable) Base density in kg/m
3
Configure process measurement
52 Micro Motion
®