Emerson 9739 Satellite Radio User Manual


 
Contents
Part I Getting Started
Chapter 1 Before you begin .............................................................................................................3
1.1 About this manual .........................................................................................................................3
1.2 Transmitter model code ................................................................................................................3
1.3 Communications tools and protocols ............................................................................................3
1.4 Additional documentation and resources ......................................................................................4
Chapter 2 Quick start .......................................................................................................................5
2.1 Power up the transmitter ...............................................................................................................5
2.2 Check flowmeter status .................................................................................................................5
2.3 Make a startup connection to the transmitter ................................................................................6
2.4 Characterize the flowmeter (if required) ........................................................................................7
2.4.1 Sample sensor tags .........................................................................................................8
2.4.2 Flow calibration parameters (FCF, FT) .............................................................................9
2.4.3 Density calibration parameters (D1, D2, K1, K2, FD, DT, TC) .........................................10
2.5 Verify mass flow measurement ....................................................................................................10
2.6 Verify the zero .............................................................................................................................11
2.6.1 Verify the zero using ProLink II ......................................................................................11
2.6.2 Terminology used with zero verification and zero calibration ........................................12
Part II Configuration and commissioning
Chapter 3 Introduction to configuration and commissioning .........................................................17
3.1 Configuration flowchart ..............................................................................................................17
3.2 Default values and ranges ............................................................................................................18
3.3 Enable access to the off-line menu of the display .........................................................................19
3.4 Disable write-protection on the transmitter configuration ..........................................................19
3.5 HART security ..............................................................................................................................19
3.6 Restore the factory configuration ................................................................................................20
Chapter 4 Configure process measurement ...................................................................................21
4.1 Configure mass flow measurement .............................................................................................21
4.1.1 Configure Mass Flow Measurement Unit .......................................................................21
4.1.2 Configure Flow Damping ..............................................................................................24
4.1.3 Configure Mass Flow Cutoff ..........................................................................................25
4.2 Configure volume flow measurement for liquid applications .......................................................26
4.2.1 Configure Volume Flow Type for liquid applications ......................................................27
4.2.2 Configure Volume Flow Measurement Unit for liquid applications ................................27
4.2.3 Configure Volume Flow Cutoff ......................................................................................30
4.3 Configure gas standard volume (GSV) flow measurement ...........................................................31
4.3.1 Configure Volume Flow Type for gas applications .........................................................32
4.3.2 Configure Standard Gas Density ....................................................................................32
4.3.3 Configure Gas Standard Volume Flow Measurement Unit .............................................33
4.3.4 Configure Gas Standard Volume Flow Cutoff ................................................................36
Contents
Configuration and Use Manual i