Options for Discrete Output Source
Options for Discrete Output SourceTable 6-8:
Option
Label
Condition
Discrete out-
put voltage
Display ProLink II ProLink III
Field Commu-
nicator
Discrete Event 1–
5
(1)
D EV x Discrete
Event x
Enhanced Event
1
Enhanced Event
2
Enhanced Event
3
Enhanced Event
4
Enhanced Event
5
Discrete
Event x
ON Site-specific
OFF 0 V
Event 1–2
(2)
EVNT1
EVNT2
E1OR2
Event 1
Event 2
Event 1 or
Event 2
Event 1
Event 2
Event 1 or Event
2 Status
Event 1
Event 2
Event 1 or
Event 2
ON Site-specific
OFF 0 V
Flow Switch
FL SW Flow Switch In-
dication
Flow Switch Indi-
cator
Flow Switch ON Site-specific
OFF 0 V
Flow Direction
FLDIR Forward/Re-
verse Indica-
tion
Forward Reverse
Indicator
Forward/Re-
verse
Forward flow 0 V
Reverse flow Site-specific
Calibration in Pro-
gress
ZERO Calibration in
Progress
Calibration in Pro-
gress
Calibration in
Progress
ON Site-specific
OFF 0 V
Fault
FAULT Fault Condition
Indication
Fault Indication
Fault ON Site-specific
OFF 0 V
Important
This table assumes that Discrete Output Polarity is set to Active High. If Discrete Output Polarity is set to Active
Low, reverse the voltage values.
Important
If you assign flow switch to the discrete output, you must also configure Flow Switch Variable, Flow
Switch Setpoint, and Hysteresis.
(1) Events configured using the enhanced event model.
(2) Events configured using the basic event model.
Integrate the meter with the control system
Configuration and Use Manual 99