Mitsubishi Electronics MR-J2S- CL Stereo Amplifier User Manual


 
11 - 6
11. TROUBLESHOOTING
Display Name Definition Cause Action
1. Servo amplifier fault caused the
parameter setting to be rewritten.
Change the servo amplifier.
2. Regenerative brake option not used
with servo amplifier was selected in
parameter No.0.
Set parameter No.0 correctly.
3. Value outside setting range has
been set in some parameter.
Set the parameter correctly.
4. Value outside setting range has
been set in electronic gear.
Set parameters No. 4, 5 correctly.
5. Opposite sign has been set in
software limit increasing side
(parameters No. 46, 47). Similarly,
opposite sign has been set in
software limit decreasing side
(parameters No. 48, 49).
Set parameters No. 46 to 49 correctly.
6. Opposite sign has been set in
position range output address
increasing side (parameters No. 50,
51). Similarly, opposite sign has
been set in position range output
address decreasing side (parameters
No. 52, 53).
Set parameters No. 50 to 53 correctly.
AL.37 Parameter
error
Parameter setting is
wrong.
7. The number of write times to EEP-
ROM exceeded 100,000 due to
parameter write, program write, etc.
Change the servo amplifier.
1. Servo amplifier fault caused the
program data to be rewritten.
Change the servo amplifier.
2. Command argument is out of the
setting range.
Programming correctly.
AL.39 Program error Program data is
abnormal
3. The number of write times to EEP-
ROM exceeded 100,000 due to
parameter write, program write, etc.
Change the servo amplifier.
1. Servo amplifier faulty. Change the servo amplifier.
2. The power supply was turned on
and off continuously by overloaded
status.
The drive method is reviewed.
AL.45 Main circuit
device overheat
Main circuit device
overheat
3. Air cooling fan of servo amplifier
stops.
1. Exchange the cooling fan or the servo
amplifier.
2. Reduce ambient temperature.
1. Ambient temperature of servo motor
is over 40
.
Review environment so that ambient
temperature is 0 to 40 .
2. Servo motor is overloaded. 1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger
output.
AL.46 Servo motor
overheat
Servo motor
temperature rise
actuated the
thermal protector.
3. Thermal protector in encoder is
faulty.
Change servo motor.