7 - 6
7. DISPLAY AND OPERATION
7.3.2 Diagnosis mode list
Name Display Description
Not ready.
Indicates that the servo amplifier is being initialized or an alarm
has occurred.
Sequence
Ready.
Indicates that the servo was switched on after completion of
initialization and the servo amplifier is ready to operate.
External I/O signal
display
Refer to section 7.6.
Indicates the ON-OFF states of the external I/O signals.
The upper segments correspond to the input signals and the
lower segments to the output signals.
Lit: ON
Extinguished: OFF
The I/O signals can be changed using the servo configuration
software.
Output signal (DO)
forced output
The digital output signal can be forced on/off. (Refer to Section
7.7)
Jog feed
Jog operation can be performed when there is no command from
the external command device. (Refer to Section 7.8.2)
Positioning
operation
The servo configuration software (MRZJW3-SETUP151E) is
required for positioning operation. This operation cannot be
performed from the operation section of the servo amplifier.
Positioning operation can be performed once when there is no
command from the external command device.
Motorless
operation
Without connection of the servo motor, the servo amplifier
provides output signals and displays the status as if the servo
motor is running actually in response to the external input
signal. (Refer to Section 7.9.4)
Test
operation
mode
Machine
analyzer
operation
Merely connecting the servo amplifier allows the resonance point
of the mechanical system to be measured.
The servo configuration software (MRZJW3-SETUP151E or later)
is required for machine analyzer operation.
Software version Low
Indicates the version of the software.
Software version High
Indicates the system number of the software.
For manufacturer
setting
Maker setting screen. Do not perform operation on this screen.