Mitsubishi Electronics MR-J2S- CL Stereo Amplifier User Manual


 
6 - 15
6. SERVO CONFIGURATION SOFTWARE
6.7 Test operation
CAUTION
The test operation mode is designed to confirm servo operation and not to confirm
machine operation. In this mode, do not use the servo motor with the machine.
Always use the servo motor alone.
If any operational fault has occurred, stop operation using the forced stop (EMG).
6.7.1 Jog operation
POINT
In the jog operation mode, do not rewrite data from the point table list
screen or the servo amplifier's front panel. Otherwise, the set values are
made invalid.
The servo motor will not operate if the forced stop (EMG), forward
rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off.
Make automatic ON setting to turn on these devices or make device
setting to assign them as external input signals and turn off across these
signals and SG. (Refer to Section 6.6.)
Hold down the “Forward” or “Reverse” button to rotate the servo motor. Release the “Forward” or
Reverse” button to stop.
Click “Test” on the menu bar and choose “Jog” on the menu.
When the above choices are made, the following window appears:
c)
d)
e)
f)
a)
b)