7 - 12
7. DISPLAY AND OPERATION
7.5.2 Operation example
(1) Parameter of 5 or less digits
The following example shows the operation procedure performed after power-on to change the home
position setting method (Parameter No.8) into the data setting type. Press the "MODE" button to
switch to the basic parameter screen.
Press four times. Select parameter No.8 withUP DOWN.orMODE
The parameter number is displayed.
UP DOWNorPress to change the number.
SETPress twice.
The set value of the specified parameter number flickers.
UPPress twice.
During flickering, the set value can be changed.
UP DOWN
or
Use .
SET
Press to enter.
( 2: Data setting type)
To shift to the next parameter, press the "UP" or "DOWN" button.
When changing the parameter No.8 (home position return type) setting, change its set value, then
switch power off once and switch it on again to make the new value valid.