Mitsubishi Electronics MR-J2S- CL Stereo Amplifier User Manual


 
5 - 7
5. PARAMETERS
Class No. Symbol Name and Function
Initial
value
Unit
Setting
range
2*OP1
Function selection 1
Used to select the input filter and absolute position detection system.
Input filter
If external input signal causes chattering due
to noise, etc., input filter is used to suppress it.
0: None
1: 0.88[ms]
2: 1.77[ms]
3: 2.66[ms]
4: 3.55[ms]
5: 4.44[ms]
Selection of absolute position detection system
(Refer to Section 4.5)
0: Incremental system
1: Absolute position detection system
00
0002 Refer to
Name
and
function
column.
Basic parameters
3ATU
Auto tuning
Used to selection the response level, etc. for execution of auto tuning.
(Refer to Chapter 7)
Auto tuning response level setting
If the machine hunts or generates large gear sound,
decrease the set value.
To improve performance, e.g. shorten the settling time,
increase the set value.
Set
value
Response
level
1
Low
response
Middle
response
High
response
Gain adjustment mode selection
(For more information, refer to Section 8.1.1.)
Machine resonance
frequency guideline
15Hz
2
20Hz
3
25Hz
4
30Hz
5
35Hz
6
45Hz
7
55Hz
8
70Hz
9
85Hz
A
105Hz
B
130Hz
C
160Hz
D
200Hz
E
240Hz
F300Hz
Set value
Gain adjustment mode
0
Description
1
3
4
Interpolation mode
GD2 (parameterNo.34), PG2 (parameterNo.35),
VG2 (parameterNo.37), VIC (parameterNo.38)
Auto tuning mode 1
Manual mode 1
Manual mode 2
2 Auto tuning mode 2
0 0
PG1 (parameterNo.7), GD2 (parameterNo.35),
PG2 (parameterNo.35), VG1 (parameterNo.36),
VG2 (parameterNo.37), VIC (parameterNo.38)
PG1 (parameterNo.7), PG2 (parameterNo.35),
VG1 (parameterNo.36), VG2 (parameterNo.37),
VIC (parameterNo.38)
PG2 (parameterNo.35)
0105 Refer to
Name
and
function
column
.