Emerson Process Management 2400S Satellite Radio User Manual


 
38 Micro Motion
®
Model 2400S Transmitters for DeviceNet
Using the Transmitter
API Object (0x69)
(1)
1 1 REAL Temperature-corrected density
2 REAL Temperature-corrected (standard) volume flow
3 REAL Temperature-corrected (standard) volume total
4 REAL Temperature-corrected (standard) volume
inventory
5 REAL Batch weighted average density
6 REAL Batch weighted average temperature
7 REAL CTL
Enhanced Density
Object (0x6A)
(2)
1 1 REAL Density at reference temperature
2 REAL Density (fixed SG units)
3 REAL Standard volume flow rate
4 REAL Standard volume flow total
5 REAL Standard volume flow inventory
6 REAL Net mass flow rate
7 REAL Net mass flow total
8 REAL Net mass flow inventory
9 REAL Net volume flow rate
10 REAL Net volume flow total
11 REAL Net volume flow inventory
12 REAL Concentration
13 REAL Density (fixed Baume units)
(1) Requires petroleum measurement application. See Section 8.13
(2) Requires enhanced density application. See Section 8.14.
Table 7-2 Summary of input assemblies
Instance ID Data description Size (bytes) Data type Description
1 • Status
•Mass flow
5•BOOL
• REAL
Mass flow
2
(1)
• Status
• Volume flow
5•BOOL
• REAL
Volume flow
3 • Status
•Mass flow
Mass total
9•BOOL
• REAL
• REAL
Mass flow and
total
4
(1)
• Status
• Volume flow
• Volume total
9•BOOL
• REAL
• REAL
Volume flow and
total
5
(1)
• Status
•Mass flow
• Temperature
• Density
• Volume flow
•Drive gain
21 • BOOL
• REAL
• REAL
• REAL
• REAL
• REAL
Basic process
variables
Table 7-1 Process data in DeviceNet objects continued
Class Instance
Attribute
ID
Data
type Description