Emerson Process Management 2400S Satellite Radio User Manual


 
Configuration and Use Manual 159
Device Profile
Device Profile IndexDisplay CodesMenus
C.6 Sensor Information Object (0x67)
83 Factory flow
signal offset at
zero flow
REAL Get NV The flow signal offset at
zero flow when calibrated
at the factory
Unit = microseconds
84 Discrete event
action code
USINT Set V The action that will be
performed by the event
specified in Attribute 85
• 1 = Start sensor zero
• 2 = Reset mass total
• 3 = Reset volume
total
• 4 = Reset API volume
total
• 5 = Reset ED volume
total
• 6 = Reset ED net
mass total
• 7 = Reset ED net
volume total
• 8 = Reset all totals
• 9 = Start/stop all
totals
• 18 = Increment ED
curve
• 21 = Reset GSV total
85 Discrete event
assignment
USINT Set NV The discrete event that is
assigned to the action
referenced in Attribute 84
• 57 = Discrete event 1
• 58 = Discrete event 2
• 59 = Discrete event 3
• 60 = Discrete event 4
• 61 = Discrete event 5
• 251 = None
(1) Service code 0x4D.
Table C-8 Sensor Information Object (0x67) – Instance 1
Attrib
ID Name Data type Service Mem Description Comments
1 Sensor serial
number
UDINT Set NV The serial number of the
sensor
2 Sensor type SHORT
STRING
Get NV A string that represents
the type of sensor
For example, F200,
CMF025
3 Sensor type
code
USINT Set NV The type of sensor • 0 = Curved tube
• 1 = Straight tube
Table C-7 Diagnostics Object (0x66) – Instance 1 continued
Attrib
ID Name Data type Service Mem Description Comments