Emerson Process Management 2400S Satellite Radio User Manual


 
Configuration and Use Manual 153
Device Profile
Device Profile IndexDisplay CodesMenus
17 Alarm status 6 UINT Get V A collection of status bits • 0x0001 = Not used
• 0x0002 = Not used
• 0x0004 = Not used
• 0x0008 = Not used
• 0x0010 = Not used
• 0x0020 = Not used
• 0x0040 = Not used
• 0x0080 = Not used
• 0x0100 = Discrete
event 0 active
• 0x0200 = Discrete
event 1 active
• 0x0400 = Discrete
event 2 active
• 0x0800 = Discrete
event 3 active
• 0x1000 = Discrete
event 4 active
• 0x2000 = Not used
• 0x4000 = Not used
• 0x8000 = Incorrect
board type
18 Alarm index USINT Set V Used to configure or read
alarm severity, or to
acknowledge alarms
See Table C-16 for
alarm index codes.
19 Alarm severity USINT Set NV The alarm severity of the
alarm that corresponds
with the alarm index
•0 = Ignore
•1 = Info
•2 = Fault
20 Drive gain REAL Get V The drive gain %
21 Raw tube period REAL Get V The tube frequency Unit = Hz
22 Live zero (mass
flow)
REAL Get V The unfiltered value of
mass flow
Configured mass flow
units
23 LPO voltage REAL Get V The left pickoff voltage Unit = volts
24 RPO voltage REAL Get V The right pickoff voltage Unit = volts
25 Board
temperature
REAL Get V The temperature on the
board
Unit = °C
26 Maximum
electronics
temperature
REAL Get V The maximum
temperature of the
electronics
Unit = °C
27 Minimum
electronics
temperature
REAL Get V The minimum
temperature of the
electronics
Unit = °C
28 Average
electronics
temperature
REAL Get V The average temperature
of the electronics
Unit = °C
29 Maximum
sensor
temperature
REAL Get V The maximum
temperature of the sensor
Unit = °C
30 Minimum sensor
temperature
REAL Get V The minimum
temperature of the sensor
Unit = °C
31 Average sensor
temperature
REAL Get V The average temperature
of the sensor
Unit = °C
Table C-7 Diagnostics Object (0x66) – Instance 1 continued
Attrib
ID Name Data type Service Mem Description Comments