Emerson Process Management 2400S Satellite Radio User Manual


 
162 Micro Motion
®
Model 2400S Transmitters for DeviceNet
Device Profile
C.8 API Object (0x69)
26 Enable offline
password
BOOL Set NV Enable or disable the
password requirement to
access the offline menu
•0 = Disabled
•1 = Enabled
27 Offline password UINT Set NV The offline password for
entering the offline menu
0–9999
28 Update period UINT Set NV The period in which the
display is updated
Unit = milliseconds
29 Process variable
index
USINT Set V The process variable in
which the precision will be
set in Attribute 30
See Table C-15 for
codes.
30 Process variable
precision
USINT Set NV The number of digits
displayed to the right of
the decimal point for the
process variable selected
with Attribute 29
0–5
31 Language USINT Set NV Display language
selection
• 0 = English
•1 = German
•2 = French
• 3 = Katakana
(1)
• 4 = Spanish
32 Enable IrDA port USINT Set NV Enable or disable the
IrDA port
•0 = Disabled
•1 = Enabled
(1) Not available in this release.
Table C-10 API Object (0x69) – Instance 1
Attrib
ID Name Data type Service Mem Description Comments
1 Temperature
corrected
density
REAL Get V Current value
2 Temperature
corrected
(standard)
volume flow
REAL Get V Current value
3 Temperature
corrected
(standard)
volume total
REAL Get
Reset
(1)
V Current value
4 Temperature
corrected
(standard)
volume
inventory
REAL Get
Reset
(2)
V Current value
5 Batch weighted
average density
REAL Get V Current value
6 Batch weighted
average
temperature
REAL Get V Current value
Table C-9 Local Display Object (0x68) – Instance 1 continued
Attrib