Emerson Process Management 2400S Satellite Radio User Manual


 
150 Micro Motion
®
Model 2400S Transmitters for DeviceNet
Device Profile
12 Alarm status 1 UINT Get V A collection of status bits • 0x0001 = NV error
(CP)
• 0x0002 = RAM error
(CP)
• 0x0004 = RTI failure
• 0x0008 = Sensor
failure
• 0x0010 =
Temperature out of
range
• 0x0020 = Calibration
failed
• 0x0040 = Other
failure
• 0x0080 = Transmitter
initializing
• 0x0100 = Not used
• 0x0200 = Not used
• 0x0400 = Simulation
mode On
• 0x0800 = Not used
• 0x1000 = Watchdog
error
• 0x2000 = Not used
• 0x4000 = Not used
• 0x8000 = Fault
13 Alarm status 2 UINT Get V A collection of status bits • 0x0001 = Not used
• 0x0002 = Not used
• 0x0004 = Not used
• 0x0008 = Not used
• 0x0010 = Density out
of range
• 0x0020 = Drive out of
range
• 0x0040 = CEM
communications error
• 0x0080 = Not used
• 0x0100 = Non-volatile
memory error (CP)
• 0x0200 = RAM error
(CP)
• 0x0400 = Sensor
failure
• 0x0800 =
Temperature out of
range
• 0x1000 = Input out of
range
• 0x2000 = Not used
• 0x4000 = Transmitter
not characterized
• 0x8000 = RTI failure
Table C-7 Diagnostics Object (0x66) – Instance 1 continued
Attrib