102 C1624M-F (9/07)
6. Select the decoder’s display language from the drop-down list. English is the default language. Other languages will be available if the
language pack has been installed.
7. Select the alarms to be triggered upon relay activation. Click the check boxes to select Alarm 1, Alarm 2, and/or Alarm 3.
8. Set up serial port. Refer to Table Y.
NOTE: In most applications, the decoder's serial port settings are not used and do not require configuration. These settings are required only in
certain applications and integrations; refer to the installation manual of the integration device for detailed instructions on configuring the serial
port settings.
Table Y. Decoder Serial Port Options and Defaults
9. Enable alarms. This window lists the available alarms by name and physical input number. Click the check box beside each alarm you want
to enable on the decoder.
10. Enable relays. This window lists the available relays by name and physical input number. Click the check box if you want to enable the relay
on the decoder.
11. Click Apply to save the settings. Click OK to exit and save the settings if not already saved. Click Cancel to exit without saving the new
settings.
Serial Port Setting Options Default Value
BPS
(bits per second)
110, 300, 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200, 230400
2400
Data bits 5, 6, 7, 8 8
Parity None, Odd, Even None
Stop bits 1, 2 1