Reconfiguring 6416SW Configuration Console
Settings
Carry out the procedures in this section only if you need to connect another
device (besides the 6416SW configuration console) to the 6416SW, and if the
other device runs at a slower baud rate, uses a different parity, or has a different
data bit value than the 6416SW's pre-configured factory settings.
For example, if you want to connect a 4800 baud modem to the 6416SW to remotely
manage the hub, you must change the factory-set default baud rate from 9600 to 4800.
To do so, you would enter the following command:
ONcoreATM> set terminal baud 48 [ENTER]
See the
ONcore Switching Hub/CELLplex 4000 ATM Command Reference Guide
for
information on the SET TERMINAL commands that allow you to reconfigure
configuration console settings.
Saving Reconfigured Configuration Console Settings
After you use the SET TERMINAL command to reset the baud rate, the parity, or the
data bit value for the 6416SW, the change is activated immediately and you lose
communication with the configuration console. The new configuration console setting is
not, however, permanently saved.
In order to save the configuration console parameters that you reconfigure with the SET
command, you must connect the new configuration console to the 6416SW, log on, and
enter the SAVE TERMINAL command. Once saved in this way, the new configuration
console settings remain stored in memory after you log off and in case of a power
failure.
For more information on how to reconfigure and save configuration console settings,
see the sections describing the SET TERMINAL commands in the
ONcore Switching
Hub/CELLplex 4000 ATM Command Reference Guide
.