![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/91/391c6dd3-e30f-49ea-aade-3e583210214f/391c6dd3-e30f-49ea-aade-3e583210214f-bg9c.png)
Cause Code: 3
Steps to Take: If the ARP-server is in another cluster (NNI links):
1. The NNI network-side/user-side definition rules have not been applied.
Check that one side of the NNI link is defined as user, and that the other side is
defined as network.
2. No logical-link has been defined for the NNI port.
Define the logical link, using the SET LOGICAL_LINK command.
3. The peer logical links do not match (bad vpi match, bad cluster match, bad
bandwidth match).
Check that the logical links on both sides do match, and if necessary, clear those
logical links are re-define them.
4. No static route has been defined, if the ONcore and the ARP-server are in different
ATM subnetworks.
Define the static routes using the SET STATIC_ROUTE command.
5. A static route was badly configured.
Check the static routes, using the SHOW STATIC_ROUTE command.
6. The VP-tunnel is defective.
Ask your VP-tunnel provider to test it.
7-26 ONcore ATM Switch/Control Module: Installation and User's Guide