LAN Emulation JOIN failed. ATM Forum LE status xx:
When this message occurs, the LEC is stopped. To restart the LEC, enter the SET
DEVICE LAN_EMULATION_CLIENT ETH command (the additional parameters will
automatically retain their previous values). For more information, see the
ONcore
Switching Hub/CELLplex 4000 ATM Command Reference Guide
.
Cause Cod: 1
Explanation: The LE version for the LEC is not compatible with the LES/BUS version.
Cause Code: 2
Explanation: The ONcore LEC parameters are incompatible with the LES/BUS. For
example, the emulated LAN type of the ONcore LEC (IEEE 802.3) does not correspond
to that of the LES.
Steps to Take:
1. Change the LES ATM address to reach a LES with the same LAN type (IEEE
802.3).
Cause Code: 4
Explanation: The same MAC address is already registered to the LES.
Steps to Take:
1. Change the ONcore hub MAC address (with the SET DEVICE
LAN_EMULATION_CLIENT command), or deregister the LEC with the same MAC
address from the LES.